TEKTRONIX TAS 485 CALIBRATION and TEKTRONIX TAS 485 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TAS 485 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TAS 485 (TAS485)   Description / Specification:    
TEKTRONIX TAS 485 4 Ch 100 MHz Analog Oscilloscope

200 MHz Analog Oscilloscope. Four channel. Rise Time: <= 1.8 ns. Defection Factor: 2 mV/div to 5 V/div, continuously variable between V/div settings. Deflection Factor DC Accuracy: ±2.5%. Bandwidth Limit: 20 MHz, independent channel control. Input Coupling: AC, DC, GND. Max Input Voltage: 400 V (DC + peak AC) derate at 20 dB/decade from 100 KHz to 13 V at 3 MHz. Input R and C: 1 M-Ohm ±1% in parallel with 20 pF ±2.0 pF. Channel Isolation: >= 50 dB at 10 MHz, >= 35 dB at 100 MHz. Vertical Control: CH1; CH2; CH3; CH4; ADD CH1 +CH2; ADD CH3+CH4; INVERT any/all channels; ALTernate or CHOP between all channels. Common Mode Rejection Ratio: >= 10:1 at 50 MHz. Main Sweep Time Base Range: 0.5 s/div to 20 ns/div (to 2 ns/div with X10 magnification). Delayed Sweep Time Base Range: 5 ms/div to 20 ns/div (to 2 ns/div with X10 magnification). Time Base Accuracy: ±2%, ±3% magnified. Delay Jitter: 25000 to 1 for sweep speeds slower than 1 ms/div. 10,000 for all other sweep speeds. Triggering Main Mode Selections: AUTO LEVEL, (with auto baseline), AUTO, NORM, TV LINE, TV FIELD (both, odd and even), SGL, SEQ. Trigger Coupling: DC, HF Reject, Noise Reject, LF Reject and AC for both Main and Delayed. Trigger Sensitivity - DC: 0.30 division from DC to 25 MHz, increasing linearly to 1.5 div at 250 MHz.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TAS 485. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEKTRONIX TAS 485 CALIBRATION and/or TEKTRONIX TAS 485 4 Ch 100 MHz Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: